Controller HF-K2.0

—simple installation

—suitable for outdoor use (protection IR65)

—5 “LCD touch display

—from 16 to 120 channels (additional outputs)

—RS485 remote control port

—flexibility in the programming of washing settings

—Power display, audio and visual alarm

—alarm output with external devices

Description

The Controller HF-K1.0 is specially designed to control and control the HF series filtration system. Equipped with a 5-inch color touch display. The control interface is easy to operate. The operator does not need to master a complex programming language.

Controlling the system from the device display includes the following functions:

-Launching the system in filtering mode;

-Complete stop of the system;

-Starting and stopping the system in backwash mode;

-Adjustable backwash cycle time.

The controller is equipped with integrated two-way pressure control (0.5-4.5V).

The device can simultaneously control up to 16 filters in the system.

 

Specifications

Options

Range Unit/note Default value

Sub-page

Quantity

0-16 шт 16 Equipment parameter settings
Main valve operation Works yes/no

Main valve operation

Backwash start mode

Differential pressure start, set time and high pressure start parameters Start time differential pressure
Filtration time 0-9999 hour / minute

1ч0с

Time parameter settings

Block backwash time

0-9999 second 10
Main valve start delay 0-9999 second

30

Main valve stop delay

0-9999 second 30
Single interval duration 0-9999 second

2

Differential pressure delay time

0-9999 second 5
Main valve cycle 0-9999 second

30

Differential pressure alarm delay time

0-9999 second 600
Start differential pressure backwash 0-99.99 bar

 

1.0

Pressure parameter settings

Excess backwash pressure at water inlet

0-99.99 bar 6.0
Water inlet overpressure alarm 0-99.99 bar

10.0

Water inlet pressure drop alarm

0-99.99 bar 3.0

Exhaust valve pressure increase

0-99.99

bar

3.5

Reducing the pressure on the exhaust valve

0-99.99 bar 2.5

Exhaust valve low pressure alarm

0-99.99 bar

2.0

Communication address

1-247 Setting the ModBus communication address 1 Pressure parameter settings
Control method remotely or locally local

Advanced settings. parameters control mode